Skip to content

Contact Us

Quinton Q-Stress

Quinton Q-Stress cardiac stress testing system

The Quinton Q-Stress is the hospital industry's gold standard. The PC-based cardiac stress system, winner of multiple awards (most recently Frost & Sullivan's Market Engineering Award) is now in its ninth generation.

NEW! – now Q-Stress is HL7 and DICOM compatible! Q-Stress has the flexibility to connect to your Healthcare IT systems in the way that works best for you to enhance your clinical workflow. Click here for the DICOM Conformance Statement.


Q-Stress is designed with you in mind. Its easy-to-learn left-to-right workflow and simple-to-understand icons and intuitive controls guide technicians through the stress test. Busy stress labs use QuikLists to enter comments quickly and efficiently.

Our proprietary algorithm, baseline wander, and motion artifact filters reduce noise and produce clean ECG tracings even at high speeds and steep grades. Perfect for pharmacological stress tests as well. Patients will appreciate getting the best test results the first time.

Features

  • Robust network connectivity – DICOM or HL7 connects with virtually everything needed for enhanced workflow. It's compatible with your echo system, nuclear camera, EMR, HIS, PACs and other healthcare IT systems; e.g., GE MUSE.
  • Full disclosure reports; allows you to save the whole exam and review it at any time by exporting to your electronic medical record (EMR) system or hospital information system (HIS).
  • In-test review of stress testing data that includes "rewind" and "freeze frame" capabilities (both industry firsts) while still viewing the live test.
  • Ectopic capture and display for heartbeats outside the sinoatrial node.
  • Fully customizable panel display, plus the flexibility to add your own user-defined protocols.
  • Risk scoring, procedural re-analysis, and extensive report formatting options.
  • Warranty: 13-Month parts and labor.

Benefits

  • Connectivity. Bi-directional communications using HL7 or DICOM enables the import of demographics, billing and procedures codes to Q-Stress. Export comprehensive test reports to help minimize documentation errors and lost billings.
  • Ease of use. The system’s Microsoft Windows compatibility (Vista or XP), left-to-right flow, and intuitive controls guide users through the procedure.
  • Accuracy. Tracings are accurate and clear, with clean waveforms even at high speeds and steep grades.
  • Instant replay. The Freeze Frame option allows you to "rewind" and view any section of any lead during the test.
  • Full disclosure. With the full disclosure option, you can save the entire cardiac stress test as a PDF and store it to your electronic records repository.
  • Easy analysis. Built-in analysis tools allow modifications for new patient data or for physiologic changes – resting cardiac data remains constant for comparison.
  • Customizable. You decide how you want your patient's cardiac test data presented. Create custom reports based on physician's preference. Easy reporting. QuikLists enable fast, efficient preparation of your reports.
 

OPERATING SYSTEM:

Windows XP / Vista Ultimate

 

POWER REQUIREMENTS:

100/120 VAC 50/60 Hz 2.5 A nominal; 200/240 VAC 50/60 Hz 1.3 A nominal

 

PROTOCOLS

Standard:

Bruce, Modified Bruce, Modified Balke, Naughton, USAF/SAM 2.0, USAF/SAM 3.3, Ramped-low, Ramped-medium, Ramped high, Åstrand (ergometer), Persantine (pharmacological)

Custom:

Unlimited custom protocols can be created

 

PATIENT MODULE:

AHA 10-electrode with pinch or snap connectors IEC 10-electrode with pinch or snap connectors (available for International only)

 

ECG

Capability:

True 12-lead

Gain:

5 mm/mV, 10 mm/mV, 20 mm/mV

Lead Groups:

Standard (Mason-Likar), Cabrera 12-lead, Frank, Canadian Bipolar

Display:

3, 6, 12 channels

Performance Standard:

AAMI-EC II: gain accuracy, frequency response, CMRR, system noise, dynamic range, and input impedance

 

DISPLAY AND ANALYSIS FILTERS:

Muscle artifact filter, baseline wander filter, 40 Hz low pass, line frequency. All filters can be turned on or of by the user

 

ECG COMPUTATIONS

Heart Rate:

Computation 6 second average updated every 2 seconds

ST Parameters:

Level and slope

Reference Point:

J Junction (QRS offset), user-selectable

QRS Detection:

ASVV (Absolute Spatial Vector Velocity), user can select any three leads

Beat Detection:

Enhanced Quinton Stress algorithm for improved beat detection

 

REPORTS

In-Test:

12-lead, average beat, 1-page write screen, continuous write screen, ectopic detail

Final:

Summary, tabular, worst case, average beats, in-test reports, trend graphs and peak exercise. Full Disclosure page addendum available with Full Disclosure option
Reports can be viewed, printed, saved in PDF format, e-mailed or faxed. XML format for data export to other systems

Custom:

Unlimited custom report available

 

OUTPUTS:

TTL pulse for QRS detection (lead is user- selectable); 3 user-selectable analog outputs using any ECG lead

 

EXTERNAL DEVICE INTERFACES

Treadmills:

TM 55/65, ST 55/65 (upgrade kit required)

Ergometers:

Corival, Ergoselect, Rehcor

Blood Pressure Monitors:

Colin BP412, Colin STBP-780 (Japan only), SunTech Tango+

 

AVAILABLE PRINTERS

Thermal:

High-resolution with automatic feed and continuous printing capability

Laser:

Optional Laser printer: compact HP laser printer with high quality print

Paper:

8.5 in x 11 in (US letter) or 210mm x 300 mm (A4)

 

NETWORK INTERFACE:

Optional Microsoft compatible networking for file storage, distribution and email.

 

EXPORT/COMMUNICATION
PROTOCOL/FORMAT:

XML, PDF , TCP/IP

 

REMOTE TECHNICAL SERVICE INTERFACE:

Remote service increases system uptime availability and decreases the user’s requirement to assist the troubleshooting process.
Available via network or desktop connections (available only in the US)

 

DISPLAY:

483 mm (19 in) LCD lat panel

 

ENVIRONMENTAL

Operating conditions:

Temperature: 50°F to 77°F (10°C to 25°C); Relative humidity: 20% to 80% non-condensing

Storage conditions:

Temperature: -14.8°F to 104°F (-26°C to 40°C); Relative humidity: 10% to 95% with condensation

Thermal paper storage:

at or below 77°F (25°C)

Electrodes storage:

at or below 86°F (30°C)

 

SAFETY AND STANDARDS:

EN 60601-1, Type CF defibrillation proof applied part
IEC 61000-4-6
IEC 61000-3-2
IEC 61000-4-2
IEC 61000-4-4
IEC 61000-4-8
IEC 61000-3-3
IEC 61000-4-3
IEC 61000-4-5
IEC 61000-4-11
RF emissions CISPR 11

 

CART DIMENSIONS AND WEIGHT:

30 in x 20 in x 36 in (762 mm x 508 mm x 914 mm); 120 lb (54 kg)

 

WARRANTY:

13 months parts and labor

 

OPTIONS:

Networking, Q-Exchange, Full Disclosure, Freeze Frame, Re-Analysis

Networking - The Quinton Q-Stress connects with virtually everything you need for enhanced workflow and maximum disclosure reports, including your HIS/EMR, email, printer, network storage, nuclear camera, and echo system.

Q-Exchange – This option enables the import of patient demographics, billing and procedure codes into Q-Stress. Recent enhancements to Q-Exchange include bi-directional communication and an increased amount of data Q-Stress can send and receive.

Risk Scoring - Include a patient's risk score based on the Duke, Framingham, and Functional Aerobic Impairment (FAI) indices with our risk-scoring option. Automatic risk scores provide additional prognostic data to clinicians and are easily added to the final report.

Full Disclosure - With the full disclosure option, you can capture and review every beat for absolute clinical confidence. Save an entire test as a PDF and send it to your desktop, to your network, and to your EMR for storage and remote viewing.

Freeze Frame - The Freeze Frame option provides you an 'instant replay' of any waveform during the test. You can “freeze” any ten-second ECG strip and compare it with “live” ECG tracings. Q-Stress prints side-by-side comparison reports, too.

Re-Analysis - With re-analysis, technicians can review a complete test after the procedure has ended. The built-in analysis tools allow modification of the original iso-electric points, J points, and timing to adjust for new patient data or to compensate for physiological changes during the test. Individual and multiple leads can be reanalyzed using new iso-electric points for a “Holter-like” review.

SunTech Tango+ - Specifically designed for use in treadmill, bicycle (ergometer), and pharmacological stress testing, the Tango+ reliably monitors blood pressure allowing you to focus on your patient. Add the SpO2 measurement option to make your stress ECG system a complete and seamless diagnostic test center. Available in English, French, Spanish, Italian, German, Portuguese, Chinese, and Japanese.

Image Unavailable Tango+ SPO2 Option with Adult Finger Sensor

Allows you to monitor your patients SpO2 levels in conjunction with their blood pressure.

Image Unavailable Thermal Z-Fold Paper, A4 Size

Thermal z-fold paper, A4, has a full 1 x 1 mm grid.

Image Unavailable Quik-Prep Stress Prep Kit

Assists with proper skin preparation and electrode placement for more accurate tracings.

Image Unavailable Stress Prep Kit with Heartline Electrodes

Convenient kit aids in proper skin preparation and electrode placement for more accurate tracings.

Cardiac Science Quik-Prep Electrode Quik-Prep Electrode

Provides optimal tracings with less prep time.

Cardiac Science All-Purpose Electrode All-Purpose Electrode

Pre-gelled electrodes have foam backing and high-quality hypoallergenic adhesive.

Cardiac Science Blue Max Monitoring Electrodes (Foam) Blue Max Monitoring Electrodes (Foam)

Feature an offset connection that helps reduce motion artifact and eases patient hookup.

Cardiac Science Blue Max Monitoring Electrodes (Vinyl) Blue Max Monitoring Electrodes (Vinyl)

Feature an offset connection that helps reduce motion artifact and eases patient hookup.

Image Unavailable Cable, Patient, 10 Lead ECG, 25" Snap AHA

Patient Cable for Q-Stress or HeartStride.

Image Unavailable Cable, Patient, 10 Lead ECG, 43" Snap AHA

Patient Cable for Q-Stress or HeartStride.

Image Unavailable Cable,Patient,10 lead ECG,43" Pinch IEC

Patient Cable for Q-Stress.

Cardiac Science Thermal Z-Fold Paper, 5.5” x 11” Thermal Z-Fold Paper, 8.5" x 11"

Easy-to-use thermal z-fold paper (8. 5 x 11 inches) features a full 1 x 1 mm grid.

Cable, Patient, 10 Lead ECG, 43" Pinch AHA

Patient Cable for Q-Stress or HeartStride.

Stress Cable 10 Lead 25 Cable, Patient, 10 Lead ECG, 25" Pinch AHA

Patient Cable for Q-Stress or HeartStride.

Cardiac Science Tango+ Blood Pressure Monitor Tango+ Blood Pressure Monitor for Q-Stress

Designed specifically for use in treadmill, ergometer, and pharmacological stress test environments.

Image Unavailable Tango+ Blood Pressure Monitor for Quest

Designed specifically for use in treadmill, ergometer, and pharmacological stress test environments.

Quinton Q-Stress connects with virtually everything needed for enhanced workflow and is compatible with:

  • XML protocols.
  • Our HeartCentrix data management system can make your workflow smoother and more powerful by integrating the Q-Stress to your host, EMR, and/or HIS.
In a busy cardiology stress testing center, everything has to connect — and Q-Stress delivers that connection.