Burdick Spiroxcard Spirometer / Pulse Oximeter
- SpiroOxCard inserts into a standard PC-card slot on a Windows handheld, laptop or PC
- Full-featured; performs all measurements performed on conventional spirometric and pulse oximeter devices
- Data cable plugs into the SpirOxCard while oximeter finger clip attaches to patient
- Uses patented, disposable, and biodegradable patient filters
- Interfaces to Office Medic software for real-time data access, reporting and archiving
- Warranty: 3-Year Parts and Labor
|
SPIROCARD SPECIFICATIONS |
|
Dimensions: |
2.09" W x 5.51" D x 1.02" H (53 mm x 140 mm x 26 mm) |
Weight: |
85 grams (less than 3 ounces) |
Certifications: |
UL CUL listed |
Warranty: |
Device 3 years return for exchange; Sensors 90 days |
|
OXIMETER SPECIFICATIONS |
|
Ranges: |
Percentage of saturation: 0 to 100%; pulse rate: 18 to 300 pulses per minute |
Accuracy: |
SpO2 (+/- 1 SD) = 70-100% +/- 2% of full scale; Pulse rate: +/- 3% (+/- 1 digit) |
Record time: |
Up to 24 hours |
Parameters: |
SpO2; pulse rate |
|
SPIROMETRY SPECIFICATIONS |
|
Ranges: |
FLOW: +/- 14 liters/second |
Volume: |
0 – 8 liters BTPS |
Accuracy: |
Complies with American Thoracic Society (ATS) Standards for Spirometry, 1994 Update |
Flow: |
+/- 5% of indication or 200 ml/sec, whichever is greater for FEF 25-75, and +/- 10% or 400 ml/sec whichever is greater for PEF |
Volume: |
+/- 3% or 50 ml, whichever is greater for FVC and FEV1 |
Parameters measured: |
FVC, FEV0.5, FEV1, FEV1/FVC, FEV3, FEV3/FVC, PEFR, FEF25%, FEF50%, FEF75%, FEF25-75%, FIVC, FIV0.5, FIV1, FIV1/FIVC, FIV3, FIV3/FIVC, PIFR, FIF50%, FIF 25-75%, FIF.21.2, FVC/FIVC, PIFR, Ext.Vol., MVV, RR, MTV, SVC |
BTPS conditions: |
Comply with American Thoracic Society Standards for Spirometry, 1994 Update |
Elevation corrections: |
0 to 15,000 feet (0 – 4,572 meters) |
Calibration: |
ATS 3-speed or standard calibration check |
Predicted normals: |
Crapo/Cherniack/Morris/Knudson 1983 Polgar/Hsu/Roberts/Warwick/ECCS |
Tests performed: |
FVC, pre/post testing, flow volume loop, MVV, SVC |
Measuring time: |
FVC, up to 30 seconds |
Printed scale: |
Flow-Volume: (vertical) .5 cm/L/S; (horizontal) 1 cm/1L Volume-Time: (vertical) 1 cm/iL; (horizontal) 1 cm/second |
|
COMPUTER REQUIREMENTS |
|
Office Medic Software: |
Desktop or laptop PC: Operating system: Windows® 98/2000/XP Home or Pro. SpirOxCard may not fit in all internal PC slots; Office Medic minimum requirements equal to operating system minimum requirements; Type II PC Card Slot; The SpiroCard may not fit into some desktop computers |
|
ORDERING INFORMATION |
||||
|
92525-01 |
SpirOxCard, |
|||
|
92526-01 |
SpiroCard, |
|||
|
010-1605-00 |
SpirOxCard or SpiroCard |
|||
|
010-1606-00 |
Pressure tubes (25 Quantity) |
|||
Mouthpieces for SpirOxCard or SpiroCard spirometer
Patented, disposable, and biodegradable plastic patient mouthpieces.
Sensor Pressure Tubes for use with SpiroOxCard and SpiroCard
For use with SpiroOxCard and SpiroCard sensors