EKG / ECG Test System

The Atria 3100 is our standard EKG / ECG test system for private practices (see the Burdick Atria 6100 for additional testing features). It follows on the success of our earlier model, the Burdick Atria 3000 ECG. Our technology assures an accurate report and gives ECG protocol choices, helps eliminate transcription errors, and improves workflow.

Features

  • Stores 50 ECG Records
  • Manual or automatic 3-, 4-, 6-, and 12-lead ECG printouts
  • Standard with wired Ethernet, wireless 802.11, and Bluetooth; complies with FAA requirements
  • Bi-directional communication with our HeartCentrix connectivity software
  • AccuPrint feature restricts ECG printing if lead wires are not properly attached
  • Option to use the University of Glasgow ECG interpretation algorithm
  • Warranty: 3-Year Parts and Labor

Benefits

  • Ease of use. The standard keyboard, dedicated functions keys, and intuitive menu make ECG testing easy.
  • Connectivity. Unlike its predecessor (the Atria 3000), the Atria 3100 comes with Ethernet connectivity as a standard feature. It's compatible with wireless 802.11 and Bluetooth, complies with FAA requirements, and has bi-directional communication with our HeartCentrix connectivity solution.
  • Convenience. The streamlined lightweight ECG unit fits into your office space and stores 50 ECG records.
  • Pediatric applications. The optional interpretation package lets you calculate interpretations down to a one-day-old infant.
  • Efficiency. The AccuPrint feature restricts ECG printing if lead wires are not properly attached, ensuring a clear printout and eliminating retakes. Flexibility. The unit manually or automatically produces high-quality 3-, 4-, 6- and 12-lead ECG printouts.
  • Confidence. Opt for the Glasgow algorithm (GRI) to consider clinically significant criteria (gender, age, race, medication and classification) to interpret patient data. (Ours improves on the basic GRI and provides brief and full interpretation statements.)
  • Longevity. This durable ECG machine is covered by an industry-leading warranty and service program for worry-free usage.

Please give me more information about the Burdick Atria 3100

My name:
My email:
My phone:
My zipcode:
What I'm looking for:
Receive Cardiac Science news and promotions by email:
Call 800.679.8703 or
 

DATA STORAGE:

50 records

 

NETWORK CONNECTION

Wired:

10/100 MBPS Ethernet via RJ45

Wireless:

802.11g (compatible with 802.11b networks), security options including WEP (64/128 bit), WPA / WPA2 (Personal and Enterprise, including AES), EAP-TLS, PEAP/MSCHAPv2, LEAP, RADIUS servers (including Microsoft IAS, Cisco ACS and Cisco Aironet 1200), roaming across WAPs of various configurations and support for mixed 802.11 / Ethernet networks.

 

POWER REQUIREMENTS

AC operation:

115/230 V AC +/-10%, 50/60 Hz at external power source

Battery operation:

14.4 V NiMH rechargeable battery pack

Battery duration:

300 pages continuous printing without communications enabled

 

PRINTOUT

Printout device:

216 mm thermal dot array

Paper dimensions:

8.5 in x 11 in (US letter) or 210 mm x 300 mm (A4)

Paper type:

Thermal sensitive (Burdick Assurance or Heartline paper recommended)

Chart speeds:

12.5, 25, 50 mm/sec

Gain:

5, 10, 20 mm/mV chest or limb (may be split)

Printout formats:

3-, 4-, 6-, or 12-channel; additional rhythm formats

 

ACQUISITION

Lead selection:

Meets IEC 60601-2-51
I, II, III, aVR, aVL, aVF , V1, V2, V3, V4, V5, V6, V4R; supports Cabrera and alternate chest lead (chest lead selection V2R thru V9R + V7,V8,V9)

Measurement (standard), Interpretation (optional):

Diagnosis, measurements and reason statements based on five demo graphic criteria

Pacemaker display capability:

Meets or exceeds ANSI/AAMI EC11-1991

Modes:

Automatic, rhythm or manual

Frequency response:

Meets or exceeds ANSI/AAMI EC11-1991 standard

Input impedance:

Meets or exceeds ANSI/AAMI EC11-1991 standard

Electrode offset tolerance:

+/- 300 mV

A/D Conversion:

8,000 samples/second, 2.5 µV LSB RTI

Artifact filter response:

40 Hz, -3db

Data storage resolution:

500 samples/second, 2.5 µV LSB RTI

 

SAFETY:

Leakage current: Patient <10 µA, chassis <100 µA; Defibrillation protection: to 5000 V, 360J

 

SAFETY STANDARDS:

ANSI/AAMI EC11-1991
UL 60601-1
CAN/CSA C22.2 no. 0-M91
EN 60601
CAN/CSA C22.2 no. 601.1S1
EN 60601-1-2:2001
CAN/CSA C22.2 no. 601.2.25, Amend. 1
EN 60601-2-51:2003
CAN/USA C22.2 no. 601.1-M90
EN 60601-1-4:2000

 

DISPLAY:

Backlit 2 x 40 character LCD

 

KEYBOARD:

Full alphanumeric keypad plus designated quick keys

 

ENVIRONMENTAL

Operating temperature:

50°F to 104°F (10°C to 40°C)

Operating relative humidity:

20% to 90%, non-condensing

Operating atmospheric pressure:

1060 hPa to 700 hPa (-500 ft to 10,000 ft reference to sea level)

Storage temperature:

-4°F to 115°F (-20°C to 45°C)

Storage relative humidity:

10% to 90%, non-condensing

Storage atmospheric pressure:

1060 hPa to 190 hPa (-500 ft to 40,000 ft reference to sea level)

 

DIMENSIONS (H x D x W):

5.5 in x 13.125 in x 15.0 in (14.0 cm x 33.4 cm x 38.1 cm)

 

WEIGHT:

11 lb (5 kg) (including external power supply)

 

WARRANTY:

3 years with return of warranty card

STANDARD CONFIGURATION

A31-1 E I 01

3100, interpretive, English, AHA accessories

 

CUSTOMIZED CONFIGURATION

A31-1

X

X

XX

 
 

E

   

Basic communications, includes Ethernet, serial, USB, analog out

 

F

   

Basic communications with fax modem

 

H

   

Basic communications with fax modem and 802.11g

 

R

   

Basic communications with 802.11g

   

I

 

With interpretation (adult, pediatric, pacemaker)

   

K

 

Measurements only

     

01

Accessory kit 1 (AHA cable, letter, 120v)

     

02

Accessory kit 2 (IEC cable, A4, 220v)

     

03

Accessory kit 3 (AHA cable, A4, 220v)

     

04

Accessory kit 4 (IEC cable, letter, 220v)

 

ACCESSORIES AND UPGRADES

040-1501-00

Upgrade kit, Bluetooth

040-1505-00

Interpretation option

040-1533-00

802.11g upgrade

716-0237-00

Burdick® Assurance® paper

047029

CardioSens® Ultra II electrodes

012-0844-00

Patient cable, AHA, 10 non-replaceable leads

007704

Patient cable, AHA, 10 replaceable leads

010-1639-01

Standard duty Atria cart

010-1728-00

Heavy duty Atria cart

Heavy Duty Cart

Heavy duty cart for use with Atria ECG.

Light Duty Cart

Light duty cart for use with Burdick ECG.

Standard Duty Cart

Standard duty cart for use with Atria ECGs.

Cardiac Science Ambu Blue Max Resting ECG Electrodes Ambu Blue Max Resting Electrocardiograph Electrodes

Latex free and come 100 to a package.

Cardiac Science Assurance 8.5 Assurance 8.5"x 11" Electrocardiograph Printing Paper

Features a red grid and perforations with blank header.

Cardiac Science CardioSens/K Resting ECG Electrodes CardioSens/K Resting ECG Electrodes

Hypo-allergenic, Karaya-based adhesive for sensitive skin.

Clear Choice Adapter Clip

Adapter lead wire clip.

ECG Patient cable, AHA, 10 non-replaceable leads

Patient cable, AHA, 10 non-replaceable leads.

Electrocardiograph Patient Cable, 10-lead AHA

ECG Patient cable, 10-Lead AHA, replaceable leads.

Cardiac Science HeartLine ECG Thermal Paper, Z-Fold, 8.5 HeartLine 8.5" x 11" Electrocardiograph Thermal Paper, Z-Fold

Features 5.91" (150 mm) red matrix grid and perforations with blank header.

ECG Connectivity

Comes with Ethernet connectivity as a standard feature. It’s compatible with wireless 802.11 and Bluetooth, complies with FAA requirements, and has bi-directional communication with our HeartCentrix connectivity solution.

When you need to move ECG data into an EMR, HeartCentrix will connect your Burdick and Quinton devices. With a single sign-on, you’ll be able to download information and orders directly to the ECG and upload the results back to the EMR.

Our EMR Partners

Our EMR partners are some
of the best in the business.
Allscripts
eClinicalWorks
Epic
GE
GEMMS
gMed
Greenway
MEDENT
Henry Shein
NextGen
Vitera
Misys

FAQs & Troubleshooting Tips

I cannot transmit a record to a network share.

Verfiy you can connect to the shared file from another computer. Verify you can print to the network printer (plain paper). If you can connect then re-check the setup of the network connection section in the Atria settings.

Lead fail message on the display?

Check to see if the patient cable is seated correctly and that the electrodes are applied in the correct location. Check to see if your electrodes are not outdated as the gel may have solidified. Check to see if you have pressed the override, if pressed then you will need to reacquire the ECG.

Missing print or no print on the paper.


Paper won’t feed into the machine.

Do you have the correct paper? Part number 716-0237-00 or 007983. Using other paper will void your warranty. Check to ensure you have the paper loaded correctly. Refer to your manual for loading instructions. If problem persists, contact Technical Support.

Unit won't power up or powers up and then shuts off.

Check and make sure the green LED is on in the back of the unit. Reseat power connection in the wall, the power "brick" and the unit. If all power connections are okay, you may have a depleted or dead battery.