Quinton Q-Stress

Cardiac Stress Test, Treadmill System

The Quinton Q-Stress is the hospital industry's gold standard. Our cardiac stress test with treadmill system is the winner of multiple awards (most recently Frost & Sullivan's Market Engineering Award). Quinton Q-Stress is now in its ninth generation.

New! Microvolt T-Wave AlternansTM for Q-Stress combines the industry’s leading cardiac stress test system with Cambridge Heart’s unique Microvolt T-Wave Alternans (MTWA) testing system, creating the most comprehensive, reimbursable cardiac risk-profiling system in the industry (US only). The Analytic Spectral Method® (ASM) detects every-other-beat patterns unique to patients at increased risk by analyzing the ECG in the frequency or spectral domain. Data shows that using frequency is superior at filtering out noise and artifact than using timing alone.

The Q-Stress cardiac stress test with treadmill system is designed with you in mind. Its easy-to-learn left-to-right workflow and simple-to-understand icons and intuitive controls guide technicians through the stress test. Busy stress labs use QuikLists to enter comments quickly and efficiently.

Our proprietary algorithm, baseline wander, and motion artifact filters reduce noise and produce clean ECG tracings even at high speeds and steep grades. Perfect for pharmacological stress tests as well. Patients will appreciate getting the best test results the first time.

And Q-Stress is HL7 and DICOM compatible! Q-Stress has the flexibility to connect to your Healthcare IT systems in the way that works best for you to enhance your clinical workflow. Click here for the DICOM Conformance Statement.

Features

  • Robust network connectivity – DICOM or HL7 connects with virtually everything needed for enhanced workflow. It's compatible with your echo system, nuclear camera, EMR, HIS, PACs and other healthcare IT systems.
  • Full disclosure reports; allows you to save the whole exam and review it at any time by exporting to your electronic medical record (EMR) system or hospital information system (HIS).
  • In-test review of stress testing data that includes "rewind" and "freeze frame" capabilities (both industry firsts) while still viewing the live test.
  • Ectopic capture and display for heartbeats outside the sinoatrial node.
  • Fully customizable panel display, plus the flexibility to add your own user-defined protocols.
  • Risk scoring, procedural re-analysis, and extensive report formatting options.
  • Warranty: 13-Month parts and labor.

Benefits

  • Connectivity. Bi-directional communications using HL7 or DICOM enables the import of demographics, billing and procedures codes to Q-Stress. Export comprehensive test reports to help minimize documentation errors and lost billings.
  • Ease of use. The system’s Microsoft Windows compatibility (Vista or XP), left-to-right flow, and intuitive controls guide users through the procedure.
  • Accuracy. Tracings are accurate and clear, with clean waveforms even at high speeds and steep grades.
  • Instant replay. The Freeze Frame option allows you to "rewind" and view any section of any lead during the test.
  • Full disclosure. With the full disclosure option, you can save the entire cardiac stress test as a PDF and store it to your electronic records repository.
  • Easy analysis. Built-in analysis tools allow modifications for new patient data or for physiologic changes – resting cardiac data remains constant for comparison.
  • Customizable. You decide how you want your patient's cardiac test data presented. Create custom reports based on physician's preference. Easy reporting. QuikLists enable fast, efficient preparation of your reports.

Please give me more information about the Quinton Q-Stress

My name:
My email:
My phone:
My zipcode:
What I'm looking for:
Receive Cardiac Science news and promotions by email:
Call 800.679.8703 or
 

OPERATING SYSTEM:

Windows XP / Vista Ultimate / Windows 7 Ultimate

 

POWER REQUIREMENTS:

100/120 VAC 50/60 Hz 2.5 A nominal; 200/240 VAC 50/60 Hz 1.3 A nominal

 

PROTOCOLS

Standard:

Bruce, Modified Bruce, Modified Balke, Naughton, USAF/SAM 2.0, USAF/SAM 3.3, Ramped-low, Ramped-medium, Ramped high, Åstrand (ergometer), Persantine (pharmacological)

Custom:

Unlimited custom protocols can be created

 

PATIENT MODULE:

AHA 10-electrode with pinch or snap connectors AHA 10-electrode replaceable lead wires with pinch connectors IEC 10-electrode with pinch or snap connectors (available for International only) IEC 10-electrode replaceable lead wires with pinch connectors (available for International only)

 

ECG

Capability:

True 12-lead

Gain:

5 mm/mV, 10 mm/mV, 20 mm/mV

Lead Groups:

Standard (Mason-Likar), Cabrera 12-lead, Frank, Canadian Bipolar

Display:

3, 6, 12 channels

Performance Standard:

AAMI-EC II: gain accuracy, frequency response, CMRR, system noise, dynamic range, and input impedance

 

DISPLAY AND ANALYSIS FILTERS:

Muscle artifact filter, baseline wander filter, 40 Hz low pass, line frequency. All filters can be turned on or of by the user

 

ECG COMPUTATIONS

Heart Rate:

Computation 6 second average updated every 2 seconds

ST Parameters:

Level and slope

Reference Point:

J Junction (QRS offset), user-selectable

QRS Detection:

ASVV (Absolute Spatial Vector Velocity), user can select any three leads

Beat Detection:

Enhanced Quinton Stress algorithm for improved beat detection

 

REPORTS

In-Test:

12-lead, average beat, 1-page write screen, continuous write screen, ectopic detail

Final:

Summary, tabular, worst case, average beats, in-test reports, trend graphs and peak exercise. Full Disclosure page addendum available with Full Disclosure option
Reports can be viewed, printed, saved in PDF format, e-mailed or faxed. XML format for data export to other systems

Custom:

Unlimited custom report available

 

OUTPUTS:

TTL pulse for QRS detection (lead is user- selectable); 3 user-selectable analog outputs using any ECG lead

 

EXTERNAL DEVICE INTERFACES

Treadmills:

TM 55/65, ST 55/65 (upgrade kit required)

Ergometers:

Corival, Ergoselect, Rehcor

Blood Pressure Monitors:

Colin BP412, Colin STBP-780 (Japan only), SunTech Tango+

 

AVAILABLE PRINTERS

Thermal:

High-resolution with automatic feed and continuous printing capability

Laser:

Optional Laser printer: compact HP laser printer with high quality print

Paper:

8.5 in x 11 in (US letter) or 210mm x 300 mm (A4)

 

NETWORK INTERFACE:

Optional Microsoft compatible networking for file storage, distribution and email.

 

EXPORT/COMMUNICATION
PROTOCOL/FORMAT:

XML, PDF , TCP/IP

 

REMOTE TECHNICAL SERVICE INTERFACE:

Remote service increases system uptime availability and decreases the user’s requirement to assist the troubleshooting process.
Available via network or desktop connections (available only in the US)

 

DISPLAY:

483 mm (19 in) LCD lat panel

 

ENVIRONMENTAL

Operating conditions:

Temperature: 50°F to 77°F (10°C to 25°C); Relative humidity: 20% to 80% non-condensing

Storage conditions:

Temperature: -14.8°F to 104°F (-26°C to 40°C); Relative humidity: 10% to 95% with condensation

Thermal paper storage:

at or below 77°F (25°C)

Electrodes storage:

at or below 86°F (30°C)

 

SAFETY AND STANDARDS:

EN 60601-1, Type CF defibrillation proof applied part
IEC 61000-4-6
IEC 61000-3-2
IEC 61000-4-2
IEC 61000-4-4
IEC 61000-4-8
IEC 61000-3-3
IEC 61000-4-3
IEC 61000-4-5
IEC 61000-4-11
RF emissions CISPR 11

 

CART DIMENSIONS AND WEIGHT:

30 in x 20 in x 36 in (762 mm x 508 mm x 914 mm); 120 lb (54 kg)

 

WARRANTY:

13 months parts and labor

 

OPTIONS:

Networking, Q-Exchange, Full Disclosure, Freeze Frame, Re-Analysis, Microvolt T-Wave Alternans

Networking - The Quinton Q-Stress connects with virtually everything you need for enhanced workflow and maximum disclosure reports, including your HIS/EMR, email, printer, network storage, nuclear camera, and echo system.

Q-Exchange – This option enables the import of patient demographics, billing and procedure codes into Q-Stress. Recent enhancements to Q-Exchange include bi-directional communication and an increased amount of data Q-Stress can send and receive.

Risk Scoring - Include a patient's risk score based on the Duke, Framingham, and Functional Aerobic Impairment (FAI) indices with our risk-scoring option. Automatic risk scores provide additional prognostic data to clinicians and are easily added to the final report.

Full Disclosure - With the full disclosure option, you can capture and review every beat for absolute clinical confidence. Save an entire test as a PDF and send it to your desktop, to your network, and to your EMR for storage and remote viewing.

Freeze Frame - The Freeze Frame option provides you an 'instant replay' of any waveform during the test. You can “freeze” any ten-second ECG strip and compare it with “live” ECG tracings. Q-Stress prints side-by-side comparison reports, too.

Re-Analysis - With re-analysis, technicians can review a complete test after the procedure has ended. The built-in analysis tools allow modification of the original iso-electric points, J points, and timing to adjust for new patient data or to compensate for physiological changes during the test. Individual and multiple leads can be reanalyzed using new iso-electric points for a “Holter-like” review.

Microvolt T-Wave Alternans (MTWA) - MTWA from Cambridge Heart allows you to assess your patients' risk for sudden cardiac arrest.

SunTech Tango+ - Specifically designed for use in treadmill, bicycle (ergometer), and pharmacological stress testing, the Tango+ reliably monitors blood pressure allowing you to focus on your patient. Add the SpO2 measurement option to make your stress ECG system a complete and seamless diagnostic test center. Available in English, French, Spanish, Italian, German, Portuguese, Chinese, and Japanese.

Image Unavailable Cable, Patient, 10 Lead ECG, 43" Pinch IEC

Patient Cable for Q-Stress.

Image Unavailable MTWA Belt and Buckle

Replacement belt and buckle for MTWA (T-Wave) patient module - for use with MTWA for Q-Stress.

MTWA Patient Lead Cable - AHA

Replacement MTWA (T-Wave) Patient Lead Cable - AHA - for use with MTWA for Q-Stress.

MTWA Sensor Kits

MTWA (T-Wave) sensor kits (set of 10) - for use with MTWA for Q-Stress.

Stress Prep Kit with Heartline Electrodes

Convenient kit aids in proper skin preparation and electrode placement for more accurate tracings.

Cardiac Science Tango+ Blood Pressure Monitor Tango+ Blood Pressure Monitor for Q-Stress

Designed specifically for use in treadmill, ergometer, and pharmacological stress test environments.

Image Unavailable Tango+ SPO2 Option with Adult Finger Sensor

Allows you to monitor your patients SpO2 levels in conjunction with their blood pressure.

Cardiac Science All-Purpose Electrode All-Purpose Electrode

Pre-gelled electrodes have foam backing and high-quality hypoallergenic adhesive.

Cardiac Science Blue Max Monitoring Electrodes (Foam) Blue Max Monitoring Electrodes (Foam)

Feature an offset connection that helps reduce motion artifact and eases patient hookup.

Cardiac Science Blue Max Monitoring Electrodes (Vinyl) Blue Max Monitoring Electrodes (Vinyl)

Feature an offset connection that helps reduce motion artifact and eases patient hookup.

Stress Cable 10 Lead 25 Cable, Patient, 10 Lead ECG, 25" Pinch AHA

Patient Cable for Q-Stress or HeartStride.

Cable, Patient, 10 Lead ECG, 25" Snap AHA

Patient Cable for Q-Stress or HeartStride.

Cable, Patient, 10 Lead ECG, 43" Pinch AHA

Patient Cable for Q-Stress or HeartStride.

Cable, Patient, 10 Lead ECG, 43" Snap AHA

Patient Cable for Q-Stress or HeartStride.

Quick-Trace ECG Electrodes Quick-Trace ECG Electrodes

Feature snap connector, perforated circular clear tape, and low-chloride hydrogel.

Cardiac Science Quik-Prep Electrode Quik-Prep Electrode

Provides optimal tracings with less prep time.

Quik-Prep Stress Prep Kit

Assists with proper skin preparation and electrode placement for more accurate tracings.

Quik-Trace Diaphoretic Snap ECG Electrodes

These are Quik-Trace diaphoretic snap foam ECG electrodes.

Thermal Z-Fold Paper, 8.5 x 11 Thermal Z-Fold Paper, 8.5" x 11"

Easy-to-use Thermal Z-Fold Paper (8.5 x 11 inches) features a full 1 x 1 mm grid.

Thermal Z-Fold Paper, A4 Size

Thermal Z-Fold Paper, A4, has a full 1 x 1 mm grid.

Quinton Q-Stress connects with virtually everything needed for enhanced workflow and is compatible with:

  • XML protocols.
  • Our HeartCentrix data management system can make your workflow smoother and more powerful by integrating the Q-Stress to your host, EMR, and/or HIS.
In a busy cardiology stress testing center, everything has to connect — and Q-Stress delivers that connection.

FAQs & Troubleshooting Tips

Can we apply Microsoft updates to our Q-Stress / Treadmill system?

No, applying Microsoft updates to the Q-Stress operating system is not recommended. The Q-Stress comes with a certified image and we do not recommend any updates.

Can we install anti-virus software on our Q-Stress / Treadmill system?

Yes, you can install anti-virus software to protect your Q-Stress system. However, our recommendation is to bypass the complete Quinton folder located under c:\program files. It is also recommended to only run updates and scans during business off hours. Running scans or updates can effect the performance of the system and we require all system resources be dedicated to the Q-Stress application.

Does Remote Support cost anything?

This service is available free of charge for our warranty and service contract customers. Billable customers are charged the standard hourly service rate.

How do I set up Remote Support on my Cardiac Science equipment?

Several methods are available. Examples of the most popular are PC Anywhere, Real VNC (Virtual Network Computing) or WebEx Intercall. Contact Technical Support for more details.

How does Remote Support benefit me?

We have the availability of experts to assist you in real time, without having to send your unit in, or sending a field service engineer on site. We can assist you with installing software and service patches. We can help identify workflow issues, verifiy versions and software settings. We can view and send log files to our FTP site. This has proved to be a valuable tool in resolving issues quickly meaning increased uptime for your equipment.

I am getting an error message that reads, "Your database has reached 90%, if you do not complete a purge you will not be able to continue using the application when it reaches 95%". What does that mean?

The error message is requesting you clean up the database through the Q-Stress Purge and archive utility located within the Q-Stress application. click on Tools > Service > Database, a window should pop up indicating "Database Service", Select the tab that indicates "purge" then select one out of the three option available. After the task is completed reboot and the error message should no longer pop up.

Is Remote Support safe and secure?

Yes. Remote Support is safe and secure. Information is shared only between your computer, and the computer of the Technician working on your issue.

My THR (target heart rate) is not calculating correctly, what could be the cause?

It is possible you did not select your patient prior to running the study. You can verify this by looking at the top of your screen which should list the patients name and MRN. If there is only a date and time listed you did not select your patient prior to checking electrodes and selecting rest.

The ECG trace on the monitor is red, how can I change it back to the standard blue?

You will need to change the resolution settings within the display options. First, close any applications that are currently running. Then right click anywhere on the desktop and select "Properties"; left click on the "Settings" tab and use the drop down menu to change the "Color Quality" from "Highest (32 bit)" to "Medium (16bit)" then select "apply" and "ok".

What is Remote Support?

Remote Support is the ability for the Cardiac Science Technical Support Team to access your PC directly. We can connect to your PC remotely and control the actions temporarily. We can also help fix problems and review log files over a secure internet connection.